The following table shows the available read command list:
Reset Device Command
The Reset feature resets the VS0102 / VS0104 / VS0108 back to the factory
default settings. The formula for the Rest commands are as follows:
Command [Enter]
For example, to reset port 02 back to the factory default settings, input the
following:
reset o02 [Enter]
The following tables show the possible values and formats for the Output
Command and Port Number command:
The following table shows the available command list:
Command Output Port Control Enter Description
read version [Enter] Read device firmware version
read edid [Enter] Read EDID information
read o yy video [Enter] Read port video on/off status
read o yy audio [Enter] Read port audio on/off status
read o * video [Enter] Read all port video on/off status
read o * audio [Enter] Read all port audio on/off status
Command Description
reset Resets the device back to the
factory default settings
Output
Command
Description
o Output Command
Port Number Description
yy 01-08 port (default is 01)
*All ports
Command Output Port Enter Description
reset o yy [Enter] Reset port to factory default settings
reset o * [Enter] Reset all ports to factory default