4.7

Out of 3 Ratings

Owner's of the HP (Hewlett-Packard) Calculator HP 12C Financial Calculator gave it a score of 4.7 out of 5. Here's how the scores stacked up:
  • Reliability

    5.0 out of 5
  • Durability

    5.0 out of 5
  • Maintenance

    5.0 out of 5
  • Performance

    5.0 out of 5
  • Ease of Use

    3.5 out of 5
of 278
 
Section 9: Branching and Looping 135
File name: hp 12c pt_user's guide_English_HDPMF123E27 Page: 135 of 275
Printed Date: 2005/8/1 Dimension: 14.8 cm x 21 cm
Keystrokes
(RPN mode)
Display
Ê
004,43, 33, 007
Condition tested by
o
was true,
so program execution continued
with line 004:
gi
007.
20,000.00
Ê
007, 45 1
Line 007:
:
1.
20.00
20% tax rate has been recalled to
X-register, moving income to
Y-register.
Ê
008, 25
Line 008:
b
.
4,000.00
20% of 20,000 = 4,000.
25000
25,000.
Keys income
g
reater than test value
into display and X-register.
Ê
001, 45 0
Line 001:
:
0.
20,000.00
Test value has been recalled to
X-register, moving income to
Y-register.
Ê
002, 34
Line 002:
~
.
25,000.00
Income has been placed in
X-register and test value has been
placed in Y-register.
Ê
003, 43 34
Line 003:
go
.
25,000.00
Ê
005, 45 2
Condition tested by
o
was false,
so program execution skipped the
next line and continued at line
005:
:
2.
25.00
25% tax rate has been recalled to
X-register, moving income to
Y-register.
Ê
006,43, 33, 008
Line 006:
gi
008.
25.00
Ê
008, 25
Line 008:
b
.
6,250.00
25% of 25,000 = 6,250.