Advanced Operation
Configuration using RS-232
To congure the IP settings of the IP to 2 x RS-232 Converter using RS-232 commands,
use the following procedure:
1. Connect a null-modem (“crossover”) cable from the RS-232 port on the computer to
the IP to 2 x RS-232 Converter.
The null-modem cable can be connected to either RS-232 1 or RS-232 2.
Diagram 2.1 - Conguration using a null-modem cable.
PC with terminal-emulation IP to 2 x RS-232 Converter
2. Use the following COM port settings in the terminal program:
Description Setting
Baud rate
19200
Data bits
8
Parity
None
Stop bits
1
Hardware ow control
None
3. Set the IP address using the #set_ipadd command.
4. Set the subnet mask using the #set_netmask command.