0

Out of 0 Ratings

Owner's of the Gefen Marine Battery Gefen Marine Battery gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 84
 
page | 40
Commands
Advanced Operation
Advanced Operation
#show_ipcong
Displays the current TCP/IP and UDP settings.
Syntax
#show_ipcong
Parameters
None
Example
#show_ipcong
--------- IP to 2 x RS-232 Converter settings ---------
MAC addr = 00:1C:91:01:0F:FF
IP addr = 10.5.64.254
Net Mask = 255.255.255.0
Gateway = 192.168.1.254
Web Server Port = 80
TCP Terminal Server Port = 23
TCP Terminal Access = Enabled
TCP Terminal password at login is set to OFF
UDP Access = Disabled
UDP Server Port = 50007
Enable UDP Echo = Disabled
UDP Remote IP = 192.168.1.80
UDP Remote Port = 50008
TCP Bridge 1 Port = 49200
TCP Bridge 2 Port = 49201
UDP Local Bridge 1 Port = 50200
UDP Remote Bridge 1 IP = 192.168.1.180, Port = 50000
UDP Remote Bridge 1 Echo = Disabled
UDP Local Bridge 2 Port = 50201
UDP Remote Bridge 2 IP = 192.168.1.181, Port = 50001
UDP Remote Bridge 2 Echo = Disabled
Discovery Mode: Enabled
Related Commands
#set_gateway
#set_http_port
#set_ipadd
#set_netmask
#set_tcp_br_port
#set_tcp_term_port
#set_udp_br_port
#set_udp_echo_br
#set_udp_port
#set_udp_remote_br
#set_udp_rip
#set_udp_rport
#use_discovery
#use_tcp_access
#use_tcp_term_pass
#use_udp_access
#use_udp_echo